SIXUNITED’s ESA248 V3 immersion liquid-cooled server solution reliably addresses the thermal challenges of high-density computing.


The power consumption and computational density of AIDC server chips continue to rise, pushing equipment power densities beyond the limits of conventional air-cooling solutions. Liquid cooling, with its advantages of high‑efficiency heat dissipation and low carbon emissions, is evolving from a “backup option” of the past into an essential configuration in the AI computing era.

 

SIXUNITED has partnered with Green Cloud Map, a technology-leading developer and manufacturer of liquid-cooling products in the industry, to deliver single-phase immersion, two-phase immersion, and cold-plate liquid-cooling solutions to customers, breaking the thermal bottleneck of high-density computing power and enabling efficient, low-carbon, stable operation of computing clusters.

 

01 Computing Power Unleashed, Liquid Cooling Ensures Reliability

 

The solution employs the SIXUNITED 4U dual-socket AI server ESA248 V3, which supports two AMD 9004/9005 series processors, each with a TDP of up to 500W. The chassis can accommodate up to 10 double-width 450W GPUs, which can be directly connected to the CPU without a PCIe switch, enabling high-density computing within limited rack space. With 24 DDR5 DIMM slots and an expansion capacity of 13 PCIe 5.0 slots plus one OCP 3.0 network card slot, it provides ample room for memory upgrades and high-speed networking.

 

Running dual‑socket processors alongside multiple GPUs in a clustered configuration also necessitates continuous, efficient heat dissipation. Liquid‑cooling integration must be tailored to the overall system design, taking into account both component thermal management and internal layout. This approach ensures that, while supporting high‑density computing, it also accommodates the operational requirements for equipment connectivity, access, and subsequent maintenance.

 


Project delivery site

 

02 Collaborative Adaptation, Reliable Operation

For immersion liquid-cooling environments, SIXUNITED starts by reorienting the server’s placement within the liquid-cooling tank, adjusting the interface layout and mechanical structure to shift from the conventional horizontal mounting method of air-cooled servers to a vertical deployment. By leveraging the liquid’s efficient heat transfer and optimizing the vertical flow field, this approach breaks through the power consumption bottleneck of individual cabinets, reduces fan energy consumption, and simultaneously enhances data center space utilization and hardware reliability.

 

Interface convergence toward the top
I/O interfaces such as the power supply and network card ports are centrally located near the top of the tank, with power and network cables routed separately along the top for streamlined management. Before removing equipment, maintenance personnel can first disconnect power and network connectivity and perform cable inspections, thereby minimizing operational challenges associated with plugging and unplugging components and managing cabling beneath the liquid surface.

 


Server nodes in the immersion environment have their cables connected from the top of the tank.

 

Lifting lug
Traditional rack-mount ears are primarily used for horizontally securing servers. Based on the vertical load-bearing characteristics of server insertion and removal, SIXUNITED has designed a dedicated lifting‑mount ear structure that allows equipment to be vertically inserted through the tank opening and within the internal space, while also providing clear operational reference points for subsequent removal and maintenance.

 


The server is mounted vertically in the tank.

 

03 Device Compatibility
In addition to server architecture adjustments, immersion liquid cooling also requires careful consideration of the compatibility between components and the cooling medium. Single-phase immersion relies on liquid circulation for heat transfer, while two-phase immersion utilizes the boiling and condensation of the coolant to exchange heat; the coolant must be compatible with cables, seals, adhesives, thermal interface materials, and connectors.

 

SIXUNITED and Green Cloud Map focus on the coordinated adaptation between servers and liquid-cooling systems, comprehensively considering material compatibility, equipment reliability, in-slot space, as well as on-site installation, cabling, and maintenance methods. By integrating efficient heat dissipation with device reliability, they provide support for the continuous and stable delivery of high-density computing power.

 

In response to customers’ cooling requirements in high-density AI computing scenarios, SIXUNITED has delivered an immersion liquid-cooling server solution that balances computational performance with efficient heat dissipation. Through the coordinated design of the entire system architecture, it not only meets current computing needs but also accommodates future expansion and maintenance, thereby supporting the continuous operation of customers’ compute clusters and providing practical guidance for equipment selection and system integration in industry applications. In light of the growing demand for AI computing infrastructure, SIXUNITED will continue to deepen the integration of hardware innovation with application needs, offering a diversified portfolio of AI computing products to serve a wide range of industries.